High performance liquid chromatographic determination of topiramate in human serum using UV detection


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
علوم پزشکی کرمانشاه
علوم پزشکی کرمانشاه

نویسندگان: غلامرضا بهرامی , امیر کیانی , بهاره محمدی , شهلا میرزایی

کلمات کلیدی: Reverse phase chromatography; HPLC; Topiramate; UV detection

نشریه: Journal of Chromatography B , 1 , 822 ,

اطلاعات کلی مقاله
hide/show

کد مقاله 10553
عنوان فارسی مقاله
عنوان لاتین مقاله High performance liquid chromatographic determination of topiramate in human serum using UV detection
نوع مقاله گزارش کوتاه (Policy Brife,Short Communication, Short Report, Brief report)
بالاترین نمایه نامه بین‌المللی ISI
سطح مقاله از مجلات برتر10%(scopus-Q1)
IF 2.391
عنوان نشریه Journal of Chromatography B
نوع نشریه خارجی ایندکس شده
شماره نشریه 1
دوره 822
تاریخ انتشار شمسی 1384/05/10
تاریخ انتشار میلادی
آدرس لینک مقاله/ همایش در شبکه اینترنت http://www.sciencedirect.com/science/article/pii/S1570023205003971
DOI
آدرس علمی (Affiliation) نویسنده متقاضی School of Pharmacy, Kermanshah University of Medical Sciences, Kermanshah, Iran

خلاصه مقاله
hide/show

Topiramate has no ultraviolet, visible or fluorescence absorption. Analysis of the drug in human serum has been reported by high performance liquid chromatography (HPLC) with either mass detector or fluorescence detection after precolumn derivatization using 9-fluorenylmethyl chloroformate as fluorescent labeling agent. This study was aimed to validate derivatization and analysis of topiramate in human serum with HPLC using UV detection. The drug was extracted from human serum by liquid–liquid extraction and subjected to derivatization with 9-fluorenylmethyl chloroformate. Analysis was performed on a phenyl column using of spectrophotometer detection operated at wavelength of 264 nm. A mixture of phosphate buffer (0.05 M) containing triethylamine (1 ml/l, v/v; pH 2.3) and methanol (28:72, v/v) at a flow rate of 2.5 ml/min was used as mobile phase. No interference was found with endogenous substances. Validity of the method was studied and the method was precise and accurate with a linearity range from 40 ng/ml to 40 g/ml. The limit of quantification was 40 ng/ml of serum. The correlation coefficient between HPLC methods using fluorescence and UV detections was studied and found to be 0.992 © 2005 Elsevier B.V. All rights reserved.

نویسندگان
hide/show

نویسنده نفر چندم مقاله نویسنده مسئول
غلامرضا بهرامیاولبلي
امیر کیانیچهارمخير
بهاره محمدیسومخير
شهلا میرزاییدومخير

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
High performance liquid chromatographic determination of topiramate.pdf1396/04/2484621دانلود